Alliance Laundry Systems 70269701R4 User Manual

Page 55

Advertising
background image

Electrical Requirements

53

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For T30 Gas and Steam Models
(For Total Machine):

Table 10

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

120V/60 Hz/1ph

L1, Neutral,

and ground

16.0

20

1

12 (3.31)

208-240V/60Hz/

1ph

L1, L2, Neutral,

and ground

8.0

10

2

14 (2.08)

100V/60Hz/1ph

L1, Neutral,

and ground

22.0

30

1

10 (5.26)

200-220V/60Hz/

1ph

L1, Neutral,

and ground

11.6

15

1

14 (2.08)

100V/50Hz/1ph

L1, Neutral,

and ground

24.2

35

1

8 (8.37)

200V/50Hz/1ph

L1, Neutral,

and ground

15.0

20

1

12 (3.31)

230-240V/50Hz/

1ph

L1, Neutral,

and ground

15.0

20

1

12 (3.31)

200-208V/60Hz/

3ph

L1, L2, L3,

and ground

6.4

10*

3

14 (2.08)

240V/60Hz/3ph

L1, L2, L3,

and ground

6.4

10*

3

14 (2.08)

200V/50Hz/3ph

L1, L2, L3,

and ground

5.8

10*

3

14 (2.08)

230-240V/50Hz/

3ph

L1, L2, L3,

and ground

7.0

10*

3

14 (2.08)

380V/50Hz/3ph

L1, L2, L3,

and ground

3.0

10*

3

14 (2.08)

400-415V/50Hz/

3ph

L1, L2, L3,

and ground

3.2

10*

3

14 (2.08)

460-480V/60Hz/

3ph

L1, L2, L3,

and ground

3.3

10*

3

14 (2.08)

*

3 Phase machines should not have fuses, breakers only.