Electrical Requirements

70269701

54

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Requirements for Electric
Models

Refer to Table 11, Table 12 and Table 13.

NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code Table 2 for 75°C
Conductors and are intended for use as a guideline
only. Electrical connections should be made only by
a qualified electrical contractor in accordance with
all applicable local and national requirements.

NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).

For 9 kW 25 Pound Electric Models:

For 12 kW 25 Pound Electric Models:

Table 11

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

400V/50Hz/3ph

L1, L2, L3,

and ground

16

20*

3

12 (3.31)

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

208V/60Hz/1ph

L1, L2, Neutral,

and ground

64

80

2

4 (21.2)

240V/60Hz/1ph

L1, L2, Neutral,

and ground

57

80

2

4 (21.2)

200V/50Hz/1ph

L1, Neutral,

and ground

63

80

1

4 (21.2)

230-240V/50Hz/

1ph

L1, Neutral,

and ground

58

80

1

4 (21.2)

200-208V/60Hz/

3ph

L1, L2, L3,

and ground

37

50*

3

6 (13.3)

200V/50Hz/3ph

L1, L2, L3,

and ground

36

50*

3

6 (13.3)

230-240V/50Hz/

3ph

L1, L2, L3,

and ground

33

50*

3

6 (13.3)

240V/60Hz/3ph

L1, L2, L3,

and ground

33

50*

3

6 (13.3)

380V/50Hz/3ph

L1, L2, L3,

and ground

20

25*

3

10 (5.26)

400-415V/50Hz/

3ph

L1, L2, L3,

and ground

18

25*

3

10 (5.26)

460-480V/60Hz/

3ph

L1, L2, L3,

and ground

16

25*

3

10 (5.26)

*

3 Phase machines should not have fuses, breakers only.