The door switch should be adjusted so the cylinder
stops when door is opened 2 inches (51 mm) plus or
minus 0.25 inch (6 mm). This switch is a normally
open switch and is closed by the hinge cam when the
door is closed. If adjustment is required, refer to
Figure 16 and proceed as follows:

1. Close door and start tumbler, slowly open

loading door. Cylinder and heat system should
shut off when door is open 2 inches (51 mm) plus
or minus 0.25 inch (6 mm).

2. Slowly close the loading door. When door is

2 inches (51 mm) from being fully closed, the
door switch actuating bracket (located on the
door) should depress the button and the switch
arm with an audible “click.”

3. If the actuating bracket does not operate the

switch at the appropriate door closure, bend the
actuating switch arm in or out to achieve proper
actuation.

CE Models Through Serial No. 0208002174

CE tumblers have a second door switch near the top of
the door (refer to Figure 16). This switch also should
be adjusted so cylinder stops when door is opened
within 0 – 2 inches (0 – 51 mm). This switch is
normally closed and is opened by the hinge cam when
the door is opened. If adjustment is needed, refer to
Figure 16 and proceed as follows:

1. Remove lower switch actuator (Figure 16) so

upper switch “click” can be heard.

2. Loosen upper door switch screws just enough so

switch can be moved left and right. Move switch
right if door opens too far before switch clicks.
Move switch left if door doesn’t open far enough
before switch clicks.

3. Retighten door switch screws and retest. Repeat

step 2 if further adjustment is needed.

4. Reinstall lower switch actuator and retest its

switch.