Connecting electrical service – Alliance Laundry Systems 70269701R4 User Manual

Page 49

Advertising
background image

Electrical Requirements

47

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Connecting Electrical Service

The following steps outline the procedure for
connecting electrical service to the tumbler.

3 Phase Models – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of
“single phasing” and causing premature
failure of the motor(s).

Electrical service must be connected using the
appropriate permanent rigid metal conduit
system.

Service conductors must be copper only.

For an existing service, determine your service voltage
and conductor amperage. Carefully review the tumbler
serial plate ratings and Electrical Requirements
section of this manual. If service is inadequate it must
be upgraded by a qualified electrical contractor. Never
connect an improper or inadequate service to any
machine.

Configuring Your Tumbler for Other
Service Voltages

Several gas and steam tumbler models have been
designed to be field convertible to other service
voltages. Refer to Table 8 for these models:

NOTE: Electric models are not field convertible
and must be connected to service specified on serial
plate.

If tumbler requires conversion for use on another
service voltage, complete the steps detailed in the
Conversion Instructions section prior to connecting
service to machine
.

If tumbler does not require conversion or has been
converted according to the Conversion Instructions
section of this manual, continue with step 1.

NOTE: The wiring diagram is located inside the
junction or contactor box.

1. For new service, install a circuit breaker or fused

disconnect of proper voltage and current rating as
close to each tumbler as possible.

2. Route service conduit from service breaker panel

or disconnect panel to tumbler service connection
box. Conduit routing should not obstruct access
for maintenance or servicing. Refer to Service/
Ground Location
.

3. Pull conductors through conduit and attach to

circuit breaker and ground connection. Secure
service ground wire to the grounding screw or
lug. Attach service conductors to appropriately
labeled positions on the terminal block. Make
sure all connections are secure.

4. Complete ferrite installation instructions for all

gas and steam OPL Micro models.

5. Check electrical service phase sequence (3 Phase

models only) as follows:

a. Energize the electrical service and

momentarily start the tumbler. Check the
direction of cylinder rotation. If the cylinder
rotates clockwise as viewed from the front,
the phase sequence is correct. If the cylinder
rotates counterclockwise, proceed with step b.

b. Disconnect power to machine, disconnect and

reverse the L1 and L2 connections on the
terminal block.

If your Serial Plate

voltage is:

Your tumbler can be

converted to the

following voltages:

120 Volt/60 Hertz/

1 Phase

208-240 Volt/60 Hertz/

1 Phase

200-220 Volt/60 Hertz/

1 Phase

100 Volt/60 Hertz/

1 Phase

200 Volt/50 Hertz/

1 Phase

100 Volt/50 Hertz/

l Phase

240 Volt/60 Hertz/

3 Phase

200-208 Volt/60 Hertz/

3 Phase

380 Volt/50 Hertz/

3 Phase

400-415 Volt/50 Hertz/

3 Phase

Table 8