High Altitude Orifice Sizing

For proper operation at altitudes above 2000 feet
(610 m), the gas orifice size must be reduced to ensure
complete combustion. Refer to Table 7.

For CE models, consult local gas supplier.

Table 7

Model

Gas

Altitude

Orifice

New Rate

feet

meters

#

inches

mm

Quantity

Part No.

(Btu/hr)*

25 Pound

Natural Gas

2001-4000

610-1220

26

0.1470

3.7

1

M401000

58,880

4001-6000

1221-1830

27

0.1440

3.7

M400998

53,760

6001-8000

1831-2440

28

0.1405

3.6

M401014

48,640

8001-10,000

2441-3050

29

0.1360

3.4

M400997

43,520

L.P. Gas

2001-6000

610-1830

43

0.0890

2.3

M406184

58,880

6001-8000

1831-2440

44

0.0860

2.2

M401011

48,640

8001-10,000

2441-3050

46

0.0810

2.1

M401003

43,520

30 Pound

Natural Gas

2001-4000

610-1220

22

0.1570

4.0

1

M402996

67,160

4001-6000

1221-1830

24

0.1520

3.9

M402980

61,320

6001-8000

1831-2440

26

0.1470

3.7

M401000

55,480

8001-10,000

2441-3050

28

0.1405

3.6

M401014

49,640

L.P. Gas

2001-6000

610-1830

42

0.0935

2.4

M403017

67,160

6001-8000

1831-2440

43

0.0890

2.3

M406184

55,480

8001-10,000

2441-3050

44

0.0860

2.2

M401011

49,640

T30

Natural Gas

2001-4000

610-1220

22

0.1570

4.0

2

M402996

134,320

4001-6000

1221-1830

24

0.1520

3.9

M402980

122,640

6001-8000

1831-2440

26

0.1470

3.7

M401000

110,960

8001-10,000

2441-3050

28

0.1405

3.6

M401014

99,280

L.P. Gas

2001-6000

610-1830

42

0.0935

2.4

M403017

134,320

6001-8000

1831-2440

43

0.0890

2.3

M406184

110,960

8001-10,000

2441-3050

44

0.0860

2.2

M401011

99,280

35 Pound

Natural Gas

2001-4000

610-1220

17

0.1730

4.4

1

M411374

82,800

4001-6000

1221-1830

18

0.1695

4.3

M402988

75,600

6001-8000

1831-2440

20

0.1610

4.1

M401002

68,400

8001-10,000

2441-3050

22

0.1570

4.0

M402996

61,200

L.P. Gas

2001-4000

610-1220

38

0.1015

2.6

M411376

82,800

4001-6000

1221-1830

39

0.0995

2.5

M401007

75,600

6001-8000

1831-2440

41

0.0960

2.4

M401015

68,400

8001-10,000

2441-3050

42

0.0935

2.4

M403017

61,200

*Btu/hr derate of 4% per 1000 feet (305 meters) of altitude.