Electrical Requirements

70269701

52

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Requirements for Gas and
Steam Models

Refer to Table 9 and Table 10.

NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code Table 2 for 75°C
Conductors and are intended for use as a guideline
only. Electrical connections should be made only by
a qualified electrical contractor in accordance with
all applicable local and national requirements.

NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).

For 25, 30 and 35 Pound Gas and Steam Models:

Table 9

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

[AWG (mm

2

)]

120V/60Hz/1ph

L1, Neutral,

and ground

12.0

15

1

14 (2.08)

208-240V/60Hz/

1ph

L1, L2, Neutral,

and ground

6.7

10

2

14 (2.08)

120V/60Hz/1ph

L1, Neutral,

and ground

7.5**

10

1

14 (2.08)

208-240V/60Hz/

1ph

L1, L2, Neutral,

and ground

4.5**

10

2

14 (2.08)

100V/60Hz/1ph

L1, Neutral,

and ground

11.0

15

1

14 (2.08)

200-220V/60Hz/

1ph

L1, Neutral,

and ground

5.8

10

1

14 (2.08)

100V/50Hz/1ph

L1, Neutral,

and ground

12.1

20

1

12 (3.31)

200V/50Hz/1ph

L1, Neutral,

and ground

7.5

10

1

14 (2.08)

230-240V/50Hz/

1ph

L1, Neutral,

and ground

7.5

10

1

14 (2.08)

200-208V/60Hz/

3ph

L1, L2, L3,

and ground

3.2

10*

3

14 (2.08)

240V/60Hz/3ph

L1, L2, L3,

and ground

3.2

10*

3

14 (2.08)

200V/50Hz/3ph

L1, L2, L3,

and ground

2.9

10*

3

14 (2.08)

230-240V/50Hz/

3ph

L1, L2, L3,

and ground

3.5

10*

3

14 (2.08)

380V/50Hz/3ph

L1, L2, L3,

and ground

1.5

10*

3

14 (2.08)

400-415V/50Hz/

3ph

L1, L2, L3,

and ground

1.6

10*

3

14 (2.08)

460-480V/60Hz/

3ph

L1, L2, L3,

and ground

1.6

10*

3

14 (2.08)

*

3 Phase machines should not have fuses, breakers only.

**

Special low Amp blower model, 25 Pound only