Maintenance action plans – ADIC SNC 5100 User Manual

Page 41

Advertising
background image

33

6-00020-02

SNC 5100

Maintenance Action Plans

This section describes the Maintenance Action Plans (MAPs) for the SNC
5100. MAPs exist for all of the SNC 5100’s component systems.

If it is clear that a particular component system is at fault in a problem
situation, go directly to the MAP for that component by consulting Table 6.

If it is not clear which component system is at fault in a problem situation,
choose one of the following options:

• Work through the Event Codes and Actions in Table 7 on page 35 in order

to determine the appropriate MAP.

• Work through the “Start MAP” on page 42 in order to determine the

appropriate MAP.

Table 6: Maintenance Action Plans Troubleshooting Table

Component Subsystem

Go To

If Event Code 42 has been reported

“Database Full MAP” on page 47

If you are unable to access SCSI or Fibre
devices

“Device Access MAP” on page 48

If SCSI I/O fails or errors on the SCSI bus are
reported

“SCSI Channel MAP” on page 50

If the SAN Connection LED is off or Fibre
Channel errors are reported

“Fibre Channel MAP” on page 61

If the SNC 5100 continually reboots or all
LEDs are off

“MAP for the SNC 5100” on
page 66

If the temperature Warning or Alarm LEDs are
on

“Temperature MAP” on page 66

If all LEDs are off or the SNC 5100 fails to
respond to any method of management

“Power MAP” on page 68

If Client and Server cannot communicate or
the Ethernet LED is off

“Ethernet MAP” on page 69

If the Client is communicating with the Server,
but the Service Terminal does not respond

“Service Port MAP” on page 75