136 Notes on connecting external arrays

Connecting XP512/XP48 Disk Arrays

When connecting an XP512/XP48 Disk Array as the external array, you must set the port’s host mode to

PC Server (0C).
Also, the port attribute must be the target or RCU target port.

Path status and examples of recovery procedures (XP512/XP48 Disk Arrays)

Table 23

shows examples of recovery procedures when the path status is not normal. When the path status

is not normal, see

Troubleshooting External Storage XP

” on page 121 and this table to recover the path

status. If you cannot restore the path, contact your HP account support representative.

Illegal request

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Response error

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Cannot detect port

There is a problem with connection to the external array. The following are

possible causes:

The fibre cable is not connected properly.

The topology setting between the external and target ports does not

match.

If the external array is connected through switches, the switches’

settings might not be appropriate.

Check if the fibre cable is connected properly, and use LUN Manager to set

the Fibre Channel port properly.

LUN Manager may have set LUN security.
Check if LUN security is enabled. If LUN security is enabled, disable LUN

security.

Table 22

Path status and examples of recovery procedures (XP1024/XP128 Disk Arrays) (continued)

Path status

Examples of recovery procedures

Table 23

Path status and examples of recovery procedures (XP512/XP48 Disk Arrays)

Path status

Examples of recovery procedures

External device setting changed

LUN Manager may have changed the LU paths’ settings.
Check the LU paths’ settings. If the LU paths’ settings changed, change the

settings back to the ones used when the volume was mapped. Or use

External Storage XP to perform the Delete LU operation, and perform the

Add LU operation again.