Add fc-connection, Syntax, Parameters – HP Insight Management-Software User Manual

Page 32: Output, Examples

Advertising
background image

add fc-connection

The -add fc-connection command adds a new FC connection to a server profile.

Syntax

-add fc-connection –profilename <profileName>
-connectionbay <ConnectionBay>
[-fabric <FabricName>]
[-speed <auto|1Gb|2Gb|4Gb|8Gb|disabled>]

Parameters

Table 11 Parameter descriptions for -add fc-connection

Optional

Required

Description

Parameter

x

The name of an existing
profile to add the new
connection to.

-profilename

x

The bay for the connection

-connectionbay

x

The name of an existing
fabric to associate with the

-fabric

connection. If the fabric
name is not specified, then
the connection will be
marked as unassigned
but associated with a
specific bay.

x

The port speed of the
connection port. Valid values

-speed

include auto, 1Gb, 2Gb,
4Gb

, 8Gb and disabled.

The default port speed is
auto

.

NOTE:

For HP 4Gb VC-FC

Modules or HP Virtual
Connect 4Gb FC Modules,
supported speed values
include: auto, 1Gb, 2Gb,
4Gb

, and disabled. If it is

set to 8Gb, the speed is
auto-negotiated by VC.

Output

The function returns the result of the add operation or a jobid if –nb is specified.

Examples

Add a new FC SAN Fabric connection to a profile:

vcemcli -add fc-connection –profilename MyNewProfile –connectionbay

5 –fabric SAN_5

Add a new FC SAN connection and configure the port speed:

vcemcli -add fc-connection –profilename MyNewProfile –connectionbay

6 –fabric SomeFabric –speed 4Gb

Add a new FC SAN connection and use next available fabric:

vcemcli -add fc-connection –profilename MyNewProfile –connectionbay

5

32

Using VCEM commands

Advertising