set fcoe-connection

The -set fcoe-connection command modifies an existing FCoE connection.

Syntax

set fcoe-connection –profilename <profileName>
-portnumber <PortNumber>
[-fabric <FabricName>]
[-speedtype <1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[–customspeed <100–10000>]
[–bootpriority <priority>]
[–bootport <portName>]
[–bootlun <LUN>]

Parameters

Table 15 Parameter descriptions for -set fcoe-connection

Optional

Required

Description

Parameter

x

The name of the profile to
which the FcOE connection
will be assigned.

-profilename

x

The port number of the
connection.

-portnumber

x

The name of the FCoE SAN
fabric to associate with the
connection.

-fabric

x

The requested operational
speed for the server port.

-speedtype

Valid values include 1Gb,
2Gb

, 4Gb,8Gb, custom,

and disabled. If the speed
type is custom, you can
configure any speed from
100Mb-10Gb in 100Mb
increments. The
-customspeed

parameter

is required if the speed type
is custom and is the
user-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.

x

IMPORTANT:

The

-customspeed

parameter

is required if the speed type
is custom.

User-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.

-customspeed

x

Controls whether the FC
HBA port is enabled for

-bootpriority

SAN boot and affects the
BIOS boot order. Valid
values include the following:

Usebios

primary

set fcoe-connection

39