Table 36 VCEM server error messages and descriptions (continued)

Error message description

NOTE:

The error message descriptions in this table use

[x] to represent variables in the error message output.

Error message number

There are more than one FCoE connection configured as
primary boot. Only one FCoE connection can be configured
as primary boot.

2747

There are more than one FCoE connection configured as
secondary boot. Only one FCoE connection can be
configured as secondary boot

2748

There is one FCoE connection configured as secondary
boot, but not one configured as primary boot.

2749

In the FCoE connection for interconnect bay , the selected
FC SAN fabric does not have a physical connection to this
port.

2750

In the FCoE connection for interconnect bay , the selected
FC SAN fabric does not exist. The FC SAN fabric must

2751

exist in the VC Domain Group to which the Server Profile
belongs.

Cannot configure FCoE connection because the specified
interconnect bay is invalid. A valid interconnect bay must
have a VC module that supports FCoE connections.

2752

In the FCoE connection for interconnect bay , the selected
port speed type is invalid. The valid values are {2}.

2753

In the FCoE connection for interconnect bay , the selected
port speed is invalid. The valid values are {2}.

2754

In the FCoE connection for interconnect bay , the custom
port speed is incorrect. The minimum and maximum port

2755

speeds cannot be empty. They must have the same value,
and the value must be a multiple of 100 Mb.

In the FCoE connection for interconnect bay , the custom
port speed is lower than the minimum allowed port speed
(Gb).

2756

In the FCoE connection for interconnect bay , the MAC
range type is not compatible with the addresses inside the
connection.

2757

In the FCoE connection for interconnect bay , the number
of MAC addresses is not correct. Each connection must
have only one MAC address.

2758

In the FCoE connection for interconnect bay , the
connection was replaced by a new one. To replace a

2759

connection, edit the Server Profile and delete the
connection, and then edit the Server Profile again and add
the new connection.

In the FCoE connection for interconnect bay , the WWN
range type is not compatible with the addresses inside the
connection.

2760

Invalid number of WWN addresses in the FCoE connection
for interconnect bay . VC Domains with multiple logical

2761

HBA ports per physical HBA port support up to 17
WWNN/WWPN pairs per physical port; otherwise, only
one WWNN/WWPN pair is supported per physical port.