HP XP Business Copy Software User Manual

Page 101

Advertising
background image

Table 39 Error Code and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code (SSB2)

Error Code (SSB1)

The volume specified as a P-VOL was an S-VOL of an XP Continuous
Access asynchronous pair. Because the consistency time of the
consistency group is not equal to the consistency time of the XP
Continuous Access asynchronous pair, the Split operation was rejected.

2094

b9a0/b9a1/b9a2/

b9a5/b9a6/b9ae/

b9af

When you performed the quick restore command, the quick restore
operation was rejected because of one of the following reasons:

The P-VOL of the XP Business Copy pair was an XP Thin Provisioning
V-VOL and the S-VOL of the XP Business Copy pair was a normal
volume.

The P-VOL of the XP Business Copy pair was a normal volume and
the S-VOL of the XP Business Copy pair was an XP Thin Provisioning
V-VOL.

2097

Because the emulation type of only one of volumes in the XP Business
Copy pair was OPEN-0V, the quick restore operation was rejected.

209b

Because the updated information about system configuration was being
backed up, the quick restore operation on the volume was rejected.

209c

Because the volume specified as the P-VOL was a FICON Data
Migration volume, the pair operation was rejected.

209e

The specified pairs contain the volumes of the XP Continuous Access
asynchronous pairs. Because the CLPRs of the P-VOL and S-VOL of the
specified pair were different, the quick restore operation was rejected.

20a0

Because the P-VOL was the XP Thin Provisioning V-VOL whose capacity
was increasing, the create pair operation was rejected.

20a2

Because the S-VOL was the XP Thin Provisioning V-VOL whose capacity
was increasing, the create pair operation was rejected.

20a3

Because the specified consistency group number was being used by
XP Snapshot, the pair operation was rejected.

20a9

Because the volume specified as the P-VOL was an XP Thin Provisioning
V-VOL and its zero data area was being discarded, the pair creation
was rejected.

20aa

Because the volume specified as the S-VOL was an XP Thin Provisioning
V-VOL and its zero data area was being discarded, the pair creation
was rejected.

20ab

Because the volume specified as the P-VOL was an XP Thin Provisioning
V-VOL and its capacity was increasing, the pair creation was rejected.

20b0

Because the volume specified as the S-VOL was an XP Thin Provisioning
V-VOL and its capacity was increasing, the pair creation was rejected.

20b1

Because the volume specified as the P-VOL was the S-VOL of FlashCopy
Mirroring V2, the pair operation was rejected.

22f6

Because the volume specified as the S-VOL was the P-VOL or the S-VOL
of FlashCopy Mirroring V2, the pair operation was rejected.

22f7

Troubleshooting When Using RAID Manager

101

Advertising
This manual is related to the following products: