background image

Table 39 Error Code and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code (SSB2)

Error Code (SSB1)

1.

Because the volume specified as the P-VOL was an intermediate
volume, the pair operation for the cascade configuration was
rejected.

2.

The pair operation was rejected because the specified P-VOL and
S-VOL were LUSE volumes but the number of volumes composing
the P-VOL did not match the number of volumes composing the
S-VOL.

2337

b9a0/b9a1/b9a2/

b9a5/b9a6/b9ae/

b9af

Because the volume specified as the P-VOL was not an XP Business
Copy P-VOL, the pairresync was rejected.

233A

Because the volume specified as the S-VOL was a root volume, the pair
operation was rejected.

233B

Because the volume specified as the S-VOL was a node volume, and
the volume specified as the P-VOL was not the P-VOL for the specified
S-VOL, the pair operation was rejected.

233C

Because the specified P-VOL and S-VOL were an L2 pair, and the L1
pair status was not PSUS, the pairsplit was rejected.

233D

Because the volume specified as the P-VOL was used as the P-VOL of
the XP Continuous Access pair (Synchronous and Asynchronous), the
pair operation was rejected.

233E

Because the volume specified as the S-VOL was the P-VOL of the XP
Continuous Access pair (Synchronous and Asynchronous) and the pair
status was not PSUS or PSUE, the pair operation was rejected.

233F

Because the volume specified as the S-VOL was the destination of XP
Auto LUN, the pair operation was rejected.

2342

Because the volume specified as the S-VOL had already been an S-VOL,
the pair creation was rejected.

2343

Because the volume specified as the S-VOL for XP Business Copy pair
operations was not an S-VOL, the pair operation was rejected.

2344

The volume specified as an S-VOL was a P-VOL of an XP Continuous
Access synchronous or asynchronous pair. Because the status of the
XP Continuous Access pair was invalid, the Pair operation was rejected.

2346

The volume specified as an S-VOL was an S-VOL of an XP Continuous
Access synchronous or asynchronous pair. Because the status of the
XP Continuous Access pair was invalid, the Pair operation was rejected.

2347

Because the volume specified as the S-VOL was an intermediate volume,
the pair creation for the cascade configuration was rejected.

234a

Because the volume specified as the S-VOL was the source volume of
XP Auto LUN, the pair operation was rejected.

234b

Because the specified P-VOL and the S-VOL for XP Business Copy pair
operations was not a pair, the pair operation was rejected.

2350

Because the volume specified as the P-VOL and the volume specified
as the S-VOL was the same one, the pair operation was rejected.

2351

Because the specified P-VOL and S-VOL was online to the host, the
quick restore operation or the reverse copy operation was rejected.

2352

Because the specified P-VOL and S-VOL was being split by using quick
split, the pair deletion was rejected.

2353

104 Troubleshooting

Advertising