Figure 12 Power supply

4. Status indicator (solid green on—normal operation; solid
amber—failure or no power)

1. Power supply

5. Handle

2. AC input connector

3. Latch

Blower module

Fan modules provide the cooling necessary to maintain the proper operating temperature within
the controller enclosure. If one fan fails, the remaining fan is capable of cooling the enclosure.

Figure 13 Blower module pulled out

2. Blower 2

1. Blower 1

Table 7 Fan status indicators

Description

Fault indicator

Status indicator

Normal operation.

Solid green

Green

Maintenance in progress.

Blinking

Amber is on or blinking, or the enclosure is powered
down.

Off

Fan failure. Green will be off. (Green and amber are
not on simultaneously except for a few seconds after
power-up.)

On

Amber

Battery module

Batteries provide backup power to maintain the contents of the controller cache when AC power
is lost and the storage system has not been shutdown properly. When fully charged the batteries
can sustain the cache contents for to 96 hours. Three batteries are used on the EVA8400 and two
batteries are used on the EVA6400.

Figure 14 (page 18)

illustrates the location of the cache

batteries and the battery status indicators. See

Table 8 (page 18)

for additional information on

the status indicators.

Blower module

17