Hsv controller cabling – HP 6400.8400 Enterprise Virtual Array User Manual

Page 18

Advertising
background image

Figure 14 Battery module

3. Battery 0

1. Status indicator

4. Battery 1

2. Fault indicator

The table below describes the battery status indicators. When a battery is first installed, the fault
indicator goes on (solid) for approximately 30 seconds while the system discovers the new battery.
Then, the battery status indicators display the battery status as described in the table below.

Table 8 Battery status indicators

Description

Fault indicator

Status indicator

Normal operation. A maintenance charge process keeps the battery fully
charged.

Off

On

Battery is undergoing a full charging process. This is the indication you
typically see after installing a new battery.

Off

Flashing

Battery fault. The battery has failed and should be replaced.

On

Off

The battery has experienced an over temperature fault.

Flashing

Off

Battery code is being updated. When a new battery is installed, it may
be necessary for the controllers to update the code on the battery to the

Flashing (fast)

Flashing (fast)

correct version. Both indicators flash rapidly for approximately 30
seconds.

Battery is undergoing a scheduled battery load test, during which the
battery is discharged and then recharged to ensure it is working properly.

Flashing

Flashing

During the discharge cycle, you will see this display. The load test occurs
infrequently and takes several hours.

HSV controller cabling

All data cables and power cables attach to the rear of the controller. Adjacent to each data
connector is a two-colored link status indicator.

Table 5 (page 16)

identifies the status conditions

presented by these indicators.

NOTE:

These indicators do not indicate whether there is communication on the link, only whether

the link can transmit and receive data.

18

EVA6400/8400 hardware