Specifying diskmaxlun, Verifying connectivity, Verifying virtual disks from the host – HP 6400.8400 Enterprise Virtual Array User Manual

Page 66: Specifying diskmaxlun verifying connectivity

Advertising
background image

ESXi 5.x

The # esxcli storage nmp device set --device
naa.6001438002a56f220001100000710000 --psp VMW_PSP_MRU

command sets

device naa.6001438002a56f220001100000710000 with an MRU multipathing policy.

The # esxcli storage nmp device set --device
naa.6001438002a56f220001100000710000 --psp VMW_PSP_FIXED

command sets

device naa.6001438002a56f220001100000710000 with a Fixed multipathing policy.

The # esxcli storage nmp device set --device
naa.6001438002a56f220001100000710000 --psp VMW_PSP_RR

command sets

device naa.6001438002a56f220001100000710000 with a RoundRobin multipathing
policy.

Specifying DiskMaxLUN

The DiskMaxLUN setting specifies the highest-numbered LUN that can be scanned by the ESX
server.

For ESX 2.5.x, the default value is 8. If more than eight LUNs are presented, you must change
the setting to an appropriate value. To set DiskMaxLUN, select Options> Advanced Settings
in the MUI, and then enter the highest-numbered LUN.

For ESX 3.x or ESX 4.x, the default value is set to the Max set value of 256. To set
DiskMaxLun

to a different value, in Virtual Infrastructure Client, select Configuration> Advance

Settings> Disk> Disk.MaxLun, and then enter the new value.

Verifying connectivity

To verify proper configuration and connectivity to the SAN:

For ESX 2.5.x, enter the # vmkmultipath -q command.

For ESX 3.x, enter the # esxcfg-mpath -l command.

For ESX 4.x or ESXi 5.x, enter the # esxcfg-mpath -b command.

For each LUN, verify that the multipathing policy is set correctly and that each path is marked on.
If any paths are marked dead or are not listed, check the cable connections and perform a rescan
on the appropriate FCA. For example:

For ESX 2.5.x, enter the # cos-rescan.sh vmhba0 command.

For ESX 3.x, ESX 4.x, or ESXi 5.x, enter the # esxcfg-rescan vmhba0 command.

If paths or LUNs are still missing, see the VMware or HP Storage documentation for troubleshooting
information.

Verifying virtual disks from the host

To verify that the host can access the virtual disks, enter the # more /proc/scsi/scsi command.

The output lists all SCSI devices detected by the server. An EVA6400/8400 LUN entry looks similar
to the following:

Host: scsi3 Channel: 00 ID: 00 Lun: 01

Vendor: HP Model: HS400 Rev:

Type: Direct-Access ANSI SCSI revision: 02

Verifying virtual disks from the host

Use the VMware vCenter management GUI to check all devices (see

Figure 25 (page 67)

).

66

Configuring application servers