Configuring virtual disks from the host – HP 6400.8400 Enterprise Virtual Array User Manual

Page 61

Advertising
background image

6.

Run vxdctl enable to notify VxVM of the changes.

7.

Verify the configuration of VxVM as shown in

Example 3 “Verifying the VxVM configuration”

(the output may be slightly different depending on your VxVM version and the array
configuration).

Example 3 Verifying the VxVM configuration

# vxddladm listsupport all | grep HP
libvxhpevale.so HP HSV300, HSV400, HSV450

# vxddladm listsupport libname=libvxhpevale.so
ATTR_NAME ATTR_VALUE
=======================================================================
LIBNAME libvxhpevale.so
VID HP
PID HSV300, HSV400, HSV450
ARRAY_TYPE A/A-A-HP
ARRAY_NAME EVA4400, EVA6400, EVA8400

# vxdmpadm listapm all | grep HP
dmphpalua dmphpalua 1 A/A-A-HP Active
# vxdmpadm listapm dmphpalua
Filename: dmphpalua
APM name: dmphpalua
APM version: 1
Feature: VxVM
VxVM version: 41
Array Types Supported: A/A-A-HP
Depending Array Types: A/A-A
State: Active

# vxdmpadm listenclosure all
ENCLR_NAME ENCLR_TYPE ENCLR_SNO STATUS ARRAY_TYPE
============================================================================
Disk Disk DISKS CONNECTED Disk
EVA84000 EVA8400 50001FE1002709E0 CONNECTED A/A-A-HP

By default, the EVA I/O policy is set to Round-Robin. For VxVM 4.1 MP1, only one path is used
for the I/Os with this policy. Therefore, HP recommends that you change the I/O policy to
Adaptive

in order to use all paths to the LUN on the primary controller.

Example 4 “Setting the

I/O policy”

shows the commands you can use to check and change the I/O policy.

Example 4 Setting the I/O policy

# vxdmpadm getattr arrayname EVA8400 iopolicy
ENCLR_NAME DEFAULT CURRENT
============================================
EVA84000 Round-Robin Round-Robin

# vxdmpadm setattr arrayname EVA8400 iopolicy=adaptive

# vxdmpadm getattr arrayname EVA8400 iopolicy
ENCLR_NAME DEFAULT CURRENT
============================================
EVA84000 Round-Robin Adaptive

Configuring virtual disks from the host

The procedure used to configure the LUN path to the array depends on the FCA driver. For more
information, see

“Installing Fibre Channel adapters” (page 48)

.

Oracle Solaris

61