Entering the wwn – HP 6400.8400 Enterprise Virtual Array User Manual

Page 31

Advertising
background image

The OCP on either controller can be used to input the WWN and password data. For more
information about the OCP, see

“Operator Control Panel” (page 14)

.

Table 9 (page 31)

lists the push-button functions when entering the WWN, WWN checksum, and

password data.

Table 9 Push button functions

Function

Button

Selects a character by scrolling up through the character list one character at a time.

Moves forward one character. If you accept an incorrect character, you can move through all 16
characters, one character at a time, until you display the incorrect character. You can then change
the character.

Selects a character by scrolling down through the character list one character at a time.

Moves backward one character.

Returns to the default display.

ESC

Accepts all the characters entered.

ENTER

Entering the WWN

Fibre Channel protocol requires that each controller pair have a unique WWN. This 16-character
alphanumeric name identifies the controller pair on the storage system. Two WWN labels attached
to the rack identify the storage system WWN and checksum. See

Figure 24 (page 31)

.

NOTE:

The WWN is unique to a controller pair and cannot be used for any other controller pair or
device anywhere on the network.

This is the only WWN applicable to any controller installed in a specific physical location,
even a replacement controller.

Once a WWN is assigned to a controller, you cannot change the WWN while the controller
is part of the same storage system.

Figure 24 Location of the World Wide Name labels

1. World Wide Name labels

Complete the following procedure to assign the WWN to each pair of controllers.
1.

Turn the power switches on both controllers off.

2.

Apply power to the rack.

Procedures for getting started

31