Replacing the failed component

CAUTION:

Components can be damaged by electrostatic discharge. Use proper anti-static

protection.

Always transport and store CRUs in an ESD protective enclosure.

Do not remove the CRU from the ESD protective enclosure until you are ready to install it.

Always use ESD precautions, such as a wrist strap, heel straps on conductive flooring, and
an ESD protective smock when handling ESD sensitive equipment.

Avoid touching the CRU connector pins, leads, or circuitry.

Do not place ESD generating material such as paper or non anti-static (pink) plastic in an ESD
protective enclosure with ESD sensitive equipment.

HP recommends waiting until periods of low storage system activity to replace a component.

When replacing components at the rear of the rack, cabling may obstruct access to the
component. Carefully move any cables out of the way to avoid loosening any connections.
In particular, avoid cable damage that may be caused by:

Kinking or bending.

Disconnecting cables without capping. If uncapped, cable performance may be impaired
by contact with dust, metal or other surfaces.

Placing removed cables on the floor or other surfaces, where they may be walked on or
otherwise compressed.

Replacement instructions

Printed instructions are shipped with the replacement part. Instructions for all replaceable components
are also included on the documentation CD that ships with the EVA6400/8400 and posted on
the web. For the latest information, HP recommends that you obtain the instructions from the web.

Go to the following website:

http://www.hp.com/support/manuals

. Under Storage, select Disk

Storage Systems, then select HP 6400/8400 Enterprise Virtual Arrays under P6000/EVA Disk
Arrays. The manuals page for the EVA6400/8400 appears. Scroll to the Service and maintenance
information section where the replacement instructions are posted.

HP controller enclosure replacement instructions

HP cache battery replacement instructions

HP controller blower replacement instructions

HP power supply replacement instructions

HP operator control panel replacement instructions

HP disk enclosure backplane replacement instructions

HP disk enclosure fan module replacement instructions

HP disk enclosure front UID interconnect board (with cable) replacement instructions

HP disk enclosure front UID replacement instructions

HP disk enclosure I/O module replacement instructions

HP disk enclosure midplane replacement instructions

HP disk enclosure power supply replacement instructions

Replacing the failed component