10 ir laser pointer, 11 startup procedures, 10 ir laser pointer -12 – EOTech CNVD-T2 Clip-On Night Vision Device - Thermal 2 User Manual

Page 34: 11 startup procedures -12

Advertising
background image

2-12

2.10 IR LASER POINTER

When the CNVD-T2 is turned on, pressing (and holding) the
Laser Button activates the IR Laser Pointer until pressure is
released from the button.

Continuous activation is accomplished by double-tapping the
Laser Button. While in continuous mode, pressing the Laser
Button again (single-tapping) turns the laser off.

When the Laser Pointer is activated, a laser reticle appears
in the eyepiece display with the word “LASER” directly
beneath. Further indication that the Laser Pointer is
activated is provided by the green Laser LED shown in
Figure 1-3.

If previously displayed, the boresight reticle is replaced by
the laser reticle when the IR Laser Pointer is activated.
Once the laser is turned off, the boresight reticle will
reappear in the eyepiece display. The laser reticle indicates
the aim point of the IR Laser Pointer within the field of view.

2.11 STARTUP PROCEDURES

For optimal performance and image clarity, the following
procedures should be accomplished in the order presented,
each time the CNVD-T2 is to be placed into operation:

1. Install batteries per section 2.2.

2. Turn on the CNVD-T2 by pressing the POWER button.

Wait approximately 5 seconds until the system begins
imaging.

3. Flip the objective lens cover over the objective lens and

perform a calibration of the CNVD-T2 as described in
section 2.16.

Advertising