2.11 STARTUP PROCEDURES (Continued)

4. Flip the objective lens cover up to rest on top of the

CNVD-T2 housing.

5. Adjust the brightness setting to a comfortable viewing

level as described in section 2.7.

6. Adjust the contrast (gain) setting to a comfortable viewing

level as described in section 2.8.

7. While looking through the eyepiece at an object at least

2m away, rotate the objective focus ring until the best
(sharpest) image is obtained.


2.12 SHUTDOWN PROCEDURES

1. Press (and hold) the POWER button for approximately 3

seconds as the messages OFF? then OFF! appear
sequentially in the eyepiece display. Release the
POWER button when the eyepiece display turns dark.

2. Close the objective lens cover.

3. Remove batteries; place batteries and the CNVD-T2 in

the soft carrying case.