MAINTENANCE AND TROUBLESHOOTING


3.1 TROUBLESHOOTING

The procedures below will help correct some of the basic
problems that may arise with the CNVD-T2. If the
equipment malfunction is not listed, or the actions listed do
not correct the fault, refer to section 3.4 for additional
guidance.

Table 3-1. Troubleshooting Procedures.

Symptom

Malfunction

Corrective Action

1. No display is

present upon

start-up.

a. CNVD-T2 is in Standby

Mode.

a. Press any arrow button to

“wake” from Standby Mode

(section 2.5).

b. Software overload.

b. Cycle CNVD-T2 power

on/off (section 2.5).

c. Brightness setting too

low.

c. Adjust brightness setting

(section 2.7).

d. Contrast setting

improperly adjusted.

d. Adjust contrast setting

(section 2.8).

e. Battery power is low or

batteries not properly

installed.

e. Install fresh batteries

(section 2.2).

f. Battery compartment

requires cleaning.

f. Clean battery compartment

(section 3.2).

Advertising