Chapter 1 General Information

Specifications are valid when the unit is calibrated at ambient temperature after a 5 minute
warmup.

Description

Value

Site Master:

Frequency Range:

S251C

625 to 2500 MHz

Frequency Accuracy (RF Source Mode):

£

75 parts per million @ 25°C*

Frequency Resolution:

10 kHz

SWR:

Range
Resolution

1.00 to 65.00
0.01

Return Loss:

Range
Resolution

0.00 to 54.00 dB
0.01 dB

**Distance-To-Fault (DTF):

Range (in meters)
Resolution (in meters)
(Rectangular Windowing)

0 to (Resolution x (dp–1)) a maximum of
1000m (3281 ft.) with a maximum of 517 points
resolution, # of data pts. = 130, 259, 517

( .

)( )

1 5

10

8

´

V

F

f

D

Where V

f

is the relative propagation velocity of

the cable .
dp is the number of data points (130, 259,
517).

D

F is F2 - F1 (in Hz.)

Insertion Loss/Gain

Range:
Resolution

RF Source

Frequency
Power Output (nominal)

RF Power Monitor:

Range

Offset Range
Resolution

–90.00 to +50.00 dB
0.01 dB

625 to 2500 MHz @ 10 kHz step
selectable, – 30 dBm or + 6 dBm

–80.0 to +80 dBm or
10.0 pW to 100.0 kW
0 to +60.0 dB
0.1 dB or
0.1 xW

Test Port, Type N

50 Ohms

***Immunity to Interfering signals

up to the level of:

on-frequency

on-channel

RF out

+10 dBm, reflection

RF in

+30 dBc, transmission

RF out

+17 dBm, reflection

Maximum Input (Damage Level):

Test Port, Type N
RF Detector

+22 dBm
+20 dBm

Measurement Accuracy:
Measurement accuracy depends on calibration components. Precision calibration load provides
a corrected directivity of 42 dB.

Table 1-1.

Performance Specifications (1 of 2)