Step 8. press the, Key, or press the, Auto scale – Anritsu S251C User Manual

Page 61: Amplitude, Marker, Figure 4-10. tma-s gain measurement

Advertising
background image

Step 8. Press the

SYS

key, then

OPTIONS, then BIAS TEE to turn on the bias tee volt-

age. The gain is the level change before and after the bias tee voltage is turned
on.

Step 9. Press the

AUTO SCALE

key, or press the

AMPLITUDE

key to adjust the top and

bottom scale, to display the gain level.

Step 10. Press the

MARKER

key and set marker set M1 to 834 MHz and marker M2 to

883 MHz.

Marker M1 set at 834 MHz indicates the receive band of the tower mounted amplifier. The
level above the 0 dB reference level is the gain of the TMA. Marker M2 set at 883 MHz in-
dicates the transmit band of the amplifier where there is no gain.

Chapter 4 Measurements

4-14

-10

-5

0

5

10

15

800

810

820

830

840

850

860

870

880

890

900

Limit : 0.00

M1

M2

Gain/Insertion Loss

2-PORT CAL

Date: 06/13/2001

Time: 15:52:43

Resolution: 130

CAL: ON(COAX)

dB

Frequency (800.0 - 906.0

M1: .01 dB @ 833.68 MHz

M2: .00 dB @ 882.99 MHz

-70

-60

-50

-40

-30

-20

-10

0

10

20

800 810 820 830 840 850 860 870 880 890 900

Limit : 0.00

M1

M2

Gain/Insertion Loss

TMA

Date: 06/13/2001

Time: 15:38:07

Resolution: 130

CAL: ON(COAX)

dB

Frequency (800.0 - 906.0 MHz)

M1: 12.90 dB @ 833.68 MHz

M2: -.92 dB @ 882.99 MHz

REFERENCE LEVEL

AFTER CALIBRATION

GAIN MEASURED WITH

BIAS TEE ACTIVATED

Figure 4-9.

TMA Gain Measurement After Calibration

Gain/Insertion Loss

TMA-S CELLULAR

M1: 13.57 dB @ 836.82 MHz

Frequency (750.0 - 925.0 MHz)

Transmission

(dB)

20

-20

-30

-40

-50

-60

-70

10

-10

0

750

775

800

825

850

875

900

925

M1

Figure 4-10.

TMA-S Gain Measurement

Advertising