Step 14. Verify the measured insertion loss against the calculated insertion loss:

Type

Attenuation (dB/ft)

´

Length (ft)

=

Loss (dB)

First Jumper LDF4-50A

0.0325

20

0.65

Main Feeder LDF5-50A

0.0186

150

2.79

Top Jumper

LDF4-50A

0.0325

10

0.325

The number of connector pairs (3) times the loss per pair (in dB) equals the con-
nector loss: 3

´ 0.14 = 0.42.

The insertion loss of the transmission system is equal to:

First Jumper loss + Main Feeder Loss + Top Jumper Loss + Connector Loss = Insertion Loss

0.65

+

2.79

+

0.325

+

0.42

=

4.19 dB

Figure 4-3 is an example of a typical transmission line cable loss trace.

Chapter 4 Measurements

4-6

Figure 4-3.

Typical Transmission Line Cable Loss Trace