Anritsu S251C User Manual

Page 68

Advertising
background image

Step 5. Disconnect the Tx (Transmit) coax from System 1 and connect it to the RF Out

port of the Site Master.

Step 6. Disconnect the Rx (Receive) coax from System 2 and connect it to the RF In

port of the Site Master.

Step 7. Adjust the scale, either manually or by using the

AUTO SCALE

key, to display

the isolation level in the center of the display.

Step 8. Press the

MARKER

key and set markers M1 and M2 to identify the receive band

of the amplifier.

Step 9. Press the

LIMIT

key and set the limit line to the estimated average signal level.

Figure 4-17 displays a typical antenna isolation measurement display.

Typical antenna-to antenna isolation measurements are made between –50 dB and –100 dB
below the 0 dB reference line established by the 2-port calibration.

4-21/4-22

Chapter 4 Measurements

Site Master S251C

T x

R x

R F In p u t

R F O u tp u t

A n ten n a

Is o latio n

L ev el

S ite Mas ter S 251C

Gain/Insertion Loss

R x

Figure 4-17.

Typical Antenna Isolation Measurement Display