Classification with current outputs, Classification with – Vaisala HMT360N User Manual

Page 80

Advertising
background image

User's Guide ______________________________________________________________________

78 __________________________________________________________________ M210744EN-C

Classification with Current Outputs

Europe (VTT)

EU (94/9/EC, ATEX100a)

II 1 G Ex ia IIC T4 Ga
VTT 09 ATEX 028 X issue No: 1

Safety factors

U

i

= 28 V, I

i

= 100 mA, P

i

= 700 mW

C

i

= 1 nF, L

i

negligibly low

Environmental specifications

T

amb

= -40 ... +60 °C (-40 ... +140 °F)

P

amb

= 0.8 ... 1.1 bar

Dust classification (with protection cover)

II 1 D (IP65 T = 70 °C)
VTT 04 ATEX 023X

USA (FM)

Classes I, II, III
Division 1, Groups A - G
Division 2, Groups A - D, F and G
FM Project ID: 3010615

Safety factors

V

max

= 28 VDC, I

max

= 100 mA

C

i

= 1 nF, L

i

= 0, P

i

= 0.7 W

T

amb

= 60 °C (140 °F), T5

Japan (TIIS)

Ex ia IIC T4
Code number: TC17897

Safety factors

U

i

= 28 VDC, I

i

= 100 mA, C

i

= 1 nF

P

i

= 0.7 W, L

i

= 0, T

amb

= 60 °C (140 °F)

Canada (CSA)

Class I

Division 1 and Division 2
Groups A, B, C, D

Class II

Division 1 and Division 2
Groups G and Coal Dust

Class III

CSA File No: 213862 0 000
CSA report: 1300863

Safety factors

T

amb

= 60 °C, T4,

Intrinsically safe when connected as per
Installation Drawing DRW213478

China (PCEC)

Ex ia II CT4
Certificate No. CE092145
Standard GB3836.1-2000 and
GB3836.4-2000

Advertising