98

COMMAND

NAME

DESCRIPTION

NO.

COMMAND SYNT

A

X

COMMAND

ARGUMENT 1

ARGUMENT 2

ARGUMENT 3

ARGUMENT 4

RESPONSE

R

Spec. Gravity G as ratio

of molecular weight.

(no units)

<V

alue>

(0.001-999.0)

OGR:<V

alue>

Example: OGR:0.105

No Argument

(ret. cur

. set.)

OGR:<V

alue>

Example: OGR:0.105

C

Critical T

emperature

and Pressure

<V

alue> Crit. T

emp.

(Deg. F) [-459–99999]

<V

alue> Crit. Pressure

(PSIA) [0-99999]

OGC:<V

alue>,<V

alue>

Example: OGC:50.0,100.0

No Argument

(ret. cur

. set.)

OGC:<V

alue>,<V

alue>

Example: OGC:50.0,100.0

Z

Compressibility factor

at flowing TP (applies

only for T/P meters)

<V

alue> [0.0 – 1.0]

OGZ:<V

alue>

Example: OGZ:0.325

No Argument

(ret. cur

. set.)

OGZ:<V

alue>

Example: OGZ:0.325

W

Molecular weight (Lb/

LbMol) (applies only for

Ratio of Densities mode)

<V

alue>

[0.0 – 9999.9]

OGW:<V

alue>

Example: OGW:18.3581

No Argument

(ret. cur

. set.)

OGW:<V

alue>

Example: OGW:18.3581

Flowing

Units

Parameters

Sets/Reads T

emperature

and Pressure parameters

for STD, NORMAL,

and Customer Actual

units.

NOTE:

Actual Units

parameters equal to the

Actual Flowing Conditions.

Customer Actual Units

Te

mperature and Pressure

can be used to change

flow conditions for

meters without T/P option.

29

FP

S

Standard Units

Temperature and

Pressure

<V

alue> STD T

emp.

(Deg. F) [-459–99999]

<V

alue> STD Pressure

(PSIA) [0-99999]

FPS:<V

alue>,<V

alue>

Example: FPS:70.0,14.7

No Argument

(ret. cur

. set.)

FPS:<V

alue>,<V

alue>

Example: FPS:70.0,14.7

N

Normal Units

Temperature and

Pressure

<V

alue> NORM T

emp.

(Deg. C) [-273–99999]

<V

alue> NORM Press

(KPa) [0-99999]

FPN:<V

alue>,<V

alue>

Example: FPN:0.0,101.3

No Argument

(ret. cur

. set.)

FPN:<V

alue>,<V

alue>

Example: FPN:0.0,101.3

C

Customer Actual Units

Flowing T

emperature

and Pressure (see

Note in description)

<V

alue> Actual T

emp.

(Deg. F) [-459–99999]

<V

alue> Act. Pressure

(PSIA) [0-99999]

FPC:<V

alue>,<V

alue>

Example: FPC:50.0,100.2

No Argument

(ret. cur

. set.)

FPC:<V

alue>,<V

alue>

Example:FPC:50.0,100.2