Aalborg Vortex Insertion User Manual
Page 96
91
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
Real T
ime
Calendar
Read and set date/time
for batter
y backed
calendar
.
16
C
R
(read calendar) Returns
current date and time.
CR:MM/DD/YYYY
,HH:MM:SS
Example:
CR:07/28/2010,12:11:52
D
(set date)
<Date string>
mm/dd/yyyy
CD:mm/dd/yyyy
Example: CD:07/28/2010
T
(set time)
<T
ime string>
hh:mm:ss
CT
: hh:mm:ss
Example: CT
:17:30:55
System
Events
Log
Read System Event
Log records from
EEPROM and sets
Events Log parameters
See list of the Diagnostic
Events below
.
NOTE: Events higher
than 0xFFFF can not
be masked.
Read Log Index
command returns:
Date - MM/DD/YYYY
T
ime - HH:MM:SS
Event Code – [0-24]
17
SL
L
Loop (when max. index
exceeded rollover to
index 0)
(New V
alue) [E or D]
SLL:<value> Example: SLL:D
No Argument
(Return current settings)
SLL:<value>
Example: SLL:D
S
Log Status: Current Index
[0-511] Rollover counter
SLS:<Index>,<Counter>
Example: SLS:97,0
M
System Event Log Mask
NOTE: Events higher than
0xFFFF can not be
masked.
<V
alue> 0x0000 T
o
0xFFFF (all 6 characters
are required)
SLM:<value>
Example: SLM:0x0013
No Argument
(Return current settings)
SLM:<value>
Example: SLM:0x0013
R
Read Log Index
<V
alue>
Index: [0-511]
SLR:Date,T
ime,Event
SLR:07/28/2010,12:11:52,22
C
Clear SysEvents Log
SLC
Flow Units
Selections
(defined in
#29)
Display/Change Meter
Flow Units:
S - Standard
A - Actual
N - Normal
18
FC
(New V
alue) [S,A,N]
FC: <V
alue> Example: FC:S
No Argument
(Returns current flow
units cond. settings)
FC: <V
alue>
Example:
FC:S