Aalborg Vortex Insertion User Manual

Page 66

Advertising
background image

61

5.3.10.11 Submenu Sensor Attenuation

This menu selection provides attenuation level for both piezo sensor amplifiers
(read only).

5.3.10.12 Submenu T/P ADC Output

This menu selection provides raw value of the ADC counts for RTD and pressure
sensor circuitry (read only). The reading only applicable for meters with optional
T/P sensors.

5.3.10.13 Submenu DAC Outputs Value

This menu selection provides current value of the DAC registers for each analog
4-20 mA output circuitry (read only).

5.3.10.14 Submenu CPU Temperature

This menu selection provides current value of the PCB and CPU temperature in
°C (read only).

5.3.11 Submenu L1 Display Menu

Use the Display Menu to set the cycle time for automatic screen sequencing used
in the PI mode, change the PI screen between static and dynamic modes, enable
or disable particular screen displayed in the PI mode.

5.3.11.1 Submenu Display Mode

Process Information screens can be configured to be static (manual control) or
dynamic (automatic sequencing). In the static mode pressing Up button, pages
through the PI screens in the forward direction, pressing Dn button, pages
through the PI screens in the reverse direction. When the last PI screen is reached,
the firmware “wraps around” and scrolls to the initial PI screen once again.

In the dynamic mode firmware initiates automatic screen sequencing with user
adjustable screen Cycle Time (see Paragraph 5.311.2 “Display Menu”). When the
last PI screen is reached, the firmware “wraps around” and scrolls to the initial PI
screen once again.

NOTE: PI screens which are masked in the Display Mask register
(see. Paragraph 5.3.11.3) will be skipped.

,

Advertising