Power Supply

The RMC7152 has a single 520 watt power supply. This power supply has the capability of operating at a 100 or 240 input

voltage. You must power down the system and then unplug the AC power cord to completely remove power from the system

before removing the power supply.

Power Supply Failure

If the power supply unit fails, the system will shut down and you will need to replace the power supply unit. Replacement

units can be ordered directly from Supermicro (see part numbers in Appendix C and contact infomation in Chapter 1).

Accessing the Inside of the System

1. Power down the system and remove the AC power cord.

2. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").

3. Next, remove the screws from the lips on either side of the cover then de- press the two buttons on the cover to release

it.

4. Push the cover away from you then lift it from the chassis to gain full access to the inside of the server.

Replacing the Power Supply

1. To remove the failed power unit, remove the two screws on the back of the power supply and a third from the front of the

power supply, which secures it to the bottom of the chassis.

2. Lift the unit straight out of the chassis. (The power cord should have already been removed.)

3. Replace the failed unit with another unit of the same wattage. You must replace it with the exact same power supply.

4. Carefully insert the new unit into position in the chassis and secure it with the two screws at the rear of the unit and the

third at the front.

5. Reconnect the power cord, replace the chassis top cover and push the unit back into the rack.

6. Finish by turning on the power switch on the power supply, then depress the power button on the front of the system.

Chapter 7 BIOS

7-1

Introduction

This chapter describes the AMI BIOS Setup Utility. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily

updated. This chapter de- scribes the basic navigation of the AMI BIOS Setup Utility setup screens.

Starting BIOS Setup Utility

How To Change the Configuration Data

To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting up.

Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a few cases when other

keys are used, such as <F1>, <F2>, etc.