Trouble on operation – CatEye PW-TR100 Power Unit User Manual

Page 64

Advertising
background image

64

PW-TR100 : POWER UNIT

Reference Guide

Trouble on operation

Trouble / Check Items / Remedy

Pressing the START/STOP/ENTER button does not start or stop measurement.

Check whether the auto-mode is turned on (with the

icon illuminating).

When the

icon illuminates, the auto-mode is on; you cannot start or stop measurement by press-

ing the button. Turn off the auto-mode. (See “Auto-mode” on page 37.)

The HR sensor ID failed (

[E]

is displayed on Display 2)

Is the main unit attached to the power unit?

If not, it cannot receive signals from the heart rate sensor.

When performing the ID check, is the main unit within 20-80 cm distance of the sensor?

The battery for the heart rate sensor is possibly depleted. After replacing the battery with a new one
(CR2032), check the heart rate sensor ID again (page 46).

Lap data cannot be stored.

Have you already completed 199 laps?

Up to 199 laps can be recorded in the data files.

Reset the computer data, or delete data files that contain several laps in order to obtain free space for
lap recording.

Is the lap time over 100 hours (Or is the trip distance in one interval over 9999.99 km)?

With these values exceeded, the lap cannot be measured.

Is the lap screen currently displayed?

When the lap screen is on - for example, immediately after lap recording or while you are on the lap
data viewing screen.

Cannot perform data storage

Does “data file” on the menu screen indicate 0% for the remaining memory, or 99 for the data file
number? (See “Data file” on page 47)

Delete unnecessary data files to increase the remaining memory or decrease the number of data files.

In menu mode, cannot change settings

Is the computer currently measuring time and/or speed?

Some settings cannot be changed when measurement is in progress Make sure that the timer and/or
speed measurement are stopped (Some menu screens require all data to be reset).

A reset has been carried out or data files have been deleted using the main unit only.

During measurement, was the Power select option set to ON?

Attach the power unit to the main unit and then delete all data files. (Refer to “Deleting all data files” on
page 48.)
If abnormal operating conditions persist, carry out formatting operation (page 12).

Measurement was carried out using a bicycle on which a power sensor (BB) and battery unit were not
installed (the Power select option was ON).

Will the unit be used with the Power select option ON?

Attach the power sensor and battery unit correctly and then delete all data files. (Refer to “Deleting all
data files” on page 48.)
If abnormal operating conditions persist, carry out formatting operation (page 12).

Will the unit be used with the Power select option OFF?

Set the Power select option to OFF and then delete all data files. (Refer to “Deleting all data files” on
page 48.)
If abnormal operating conditions persist, carry out formatting operation (page 12).