53

B.

OEM FRONT PANEL INDICATORS &

CONTROLS

The simulated OEM front panel illustrations to the right, and

switch and indicator operational descriptions have been pro-

vided to assist the OEM user in identifying and operating the

750 Series II Monitor/controllers.

Refer to Section V.C. for Setup procedures, and Section V.D. for

Check-Out procedures.

1. RED “HIGH SET POINT” LED INDICATOR

The red LED indicator light is ON only when the water’s conduc-

tivity/TDS reading is HIGH or ABOVE the set point adjustment

(LOW or BELOW on Resistivity). May be reversed if desired.

2. GREEN “LOW SET POINT” LED INDICATOR

The green LED indicator light is ON only when the water’s

conductivity/TDS reading is LOW or BELOW the set point

adjustment (HIGH or ABOVE on Resistivity). May be reversed if

desired.

3. “SET POINT” SWITCH(ES)

When the “SET POINT” switch is depressed, the internal set

point reading is immediately displayed on the front panel dis-

play. See figures IV.B.1 thru 4.

4. ANALOG METER OR DIGITAL DISPLAY

Panel mounted analog meter or digital display provide a continu-

ous readout of the water being monitored.

Conductivity/TDS Models 756II & 757II and Resistivity Models

751II & 752II are equipped with analog meter only as shown in

figure IV.B.4.

Conductivity/TDS Models 758II & 759II and Resistivity Models

753II & 754II are equipped with a 3 1/2 digit, 1/2” Liquid Crystal

Digital Display, as shown in figures IV.B.1 thru 3 & 5., with a 4

1/2 digit backlit LCD as an option.

5. OPTIONAL PANEL MOUNTED ITEMS

TP/TPO Module Switch

A digital Monitor/controller with the optional TP/TPO Temperature

Module has an additional switch on the front panel as shown in

figure IV.B.1. This push-button momentary switch when pushed

gives the user a direct reading of the temperature of the solution

from 0-200°C. Additional option TH/THO includes a control

function capability. See figure IV.B.1.

Full Scale Test Switch (PTS/FST)

This optional feature allows the user to see the Full Scale TEST

value without opening the panel to push the internal switch. See

figures IV.B.1 and IV.B.3 for typical examples.

Piezo Alarm

Audible alarm sounds off automatically when the set point is

reached. Mounted by OEM in any convenient location as shown

in figure IV.B.3.

WARNING: THE DISPLAY WILL BE IRREPARABLY

DAMAGED IF THE HARNESS IS INSTALLED UPSIDE-

DOWN. THE HARNESS MUST BE INSTALLED AS

SHOWN IN FIGURE II.E.6.

HIGH

LOW

SET POINT

TEMPERATURE

TEMPERATURE

FST

Figure IV.B.1

HIGH

LOW

SET POINT

Figure IV.B.2

Digital Conductivity

Monitor/controller with

optional Dual

Alarm/controls

Digital Conductivity

Monitor/controller with

optional Dual

Alarm/controls, and

Temperature with

control function, and

Front Panel Test

Switch.

758II-121-SC-TP-THH-PTS

758II-121-SC

Figure IV.B.5

HIGH

LOW

SET POINT

Figure IV.B.4

0

5

4

3

2

1

Figure IV.B.3

HIGH

LOW

SET POINT

FST

NOTE: Boxes around displays to simulate OEM

panels.

Analog Conductivity

Monitor/controller

(Single Alarm/control)

Digital Conductivity

Monitor/controller with

optional Front Panel

Test Switch, Single

Alarm/control, and

Piezo Alarm.

Digital

Resistivity

Monitor

754II-11

757II-112

758II-121-PTS-PA

Advertising
This manual is related to the following products: