AMD Geode™ SC1200/SC1201 Processor Data Book

111

SuperI/O Module

32579B

5.5.3

RTC Registers

The RTC registers can be accessed (see Section 5.4.2.1
"LDN 00h - Real-Time Clock" on page 98)
at any time dur-
ing normal operation mode (i.e.,when V

SB

is within the rec-

ommended operation range). This access is disabled
during battery-backed operation. The write operation to
these registers is also disabled if bit 7 of the CRD Register
is 0.

Note:

Before attempting to perform any start-up proce-
dures, read about bit 7 (VRT) of the CRD Register.

This section describes the RTC Timing and Control Regis-
ters that control basic RTC functionality.

Table 5-19. RTC Register Map

Index

Type

Name

Reset

Type

00h

R/W

SEC. Seconds Register

V

PP

PUR

01h

R/W

SECA. Seconds Alarm Register

V

PP

PUR

02h

R/W

MIN. Minutes Register

V

PP

PUR

03h

R/W

MINA. Minutes Alarm Register

V

PP

PUR

04h

R/W

HOR. Hours Register

V

PP

PUR

05h

R/W

HORA. Hours Alarm Register

V

PP

PUR

06h

R/W

DOW. Day Of Week Register

V

PP

PUR

07h

R/W

DOM. Date Of Month Register

V

PP

PUR

08h

R/W

MON. Month Register

V

PP

PUR

09h

R/W

YER. Year Register

V

PP

PUR

0Ah

R/W

CRA. RTC Control Register A

Bit specific

0Bh

R/W

CRB. RTC Control Register B

Bit specific

0Ch

RO

CRC. RTC Control Register C

Bit specific

0Dh

RO

CRD. RTC Control Register D

V

PP

PUR

Programmable

1

R/W

DOMA. Date of Month Alarm Register

V

PP

PUR

Programmable

1

R/W

MONA. Month Alarm Register

V

PP

PUR

Programmable

1

R/W

CEN. Century Register

V

PP

PUR

1.

Overlaid on RAM bytes in range 0Eh-7Fh. See Section 5.4.2.1 "LDN 00h - Real-Time Clock" on page 98.

Table 5-20. RTC Registers

Bit

Description

Index 00h

Seconds Register - SEC (R/W)

Reset Type: V

PP

PUR

7:0

Seconds Data. Values may be 00 to 59 in BCD format or 00 to 3B in binary format.

Index 01h

Seconds Alarm Register - SECA (R/W)

Reset Type: V

PP

PUR

7:0

Seconds Alarm Data. Values may be 00 to 59 in BCD format or 00 to 3B in binary format.

When bits 7 and 6 are both set to one (“11”), unconditional match is selected.

Index 02h

Minutes Register - MIN (R/W)

Reset Type: V

PP

PUR

7:0

Minutes Data. Values can be 00 to 59 in BCD format, or 00 to 3B in binary format.