The fault indicator lights amber, The fdd indicator does not light – Toshiba Magnia 3310 User Manual

Page 218

Advertising
background image

Troubleshooting
Troubleshooting

202

The fault indicator lights amber

A probable cause is that the cooling fan or power unit is
malfunctioning. The server enables the redundant configuration,
so check whether or not Windows Server 2003/Windows 2000 is
usable. If Windows Server 2003/Windows 2000 can be used,
proceed to “Remedy When Windows Server 2003/ Windows
2000 is usable” on page 208.

If Windows Server 2003/Windows 2000 cannot be used, turn off
the power first, and then proceed to “Remedy When Windows
Server 2003/ Windows 2000 is unusable” on page 210.

See “(6) System status indicators” on page 14.

See “Cooling fan” on page 67.

See “Power supply unit” on page 141.

The FDD indicator does not light

Probable causes are that the floppy disk drive unit signal cable is
not properly connected, or that the floppy disk drive unit itself is
malfunctioning. Check the power cable and signal cable
connections. If this does not remedy the problem, turn off the
power first, and then proceed to “Remedy When Windows Server
2003/ Windows 2000 is unusable” on page 210.

An error is displayed during POST operation, or POST stops
midway

Probable causes are a motherboard, CPU, memory or keyboard
malfunction, or that the BIOS setup is incompatible. Carry out the
following procedure to check the cause of the trouble. If Windows
Server 2003/Windows 2000 can be used, proceed to “Remedy
When Windows Server 2003/ Windows 2000 is usable” on page
208.

If Windows Server 2003/Windows 2000 cannot be used, turn off
the power first, and then proceed to “Remedy When Windows
Server 2003/ Windows 2000 is unusable” on page 210.

See “POST (Power On Self-Test)” on page 42.

Advertising