TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic

Technical Service Department.

• Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-

nel.

• All electronic components have 120 volt ac and/or low voltage dc potential on their terminals. Shorting of

terminals or the application of external voltages may result in board failure.

• Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If

an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a

terminal or crimp.

• Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the dispenser when servicing, except when electrical tests are specified.

• Follow recommended service procedures

• Replace all protective shields or safety notices

No Power

Correct voltage

at outlet?

No

Yes

Call licensed

electrician for repair

12vac to Control Board

at J5-8 & J5-20?

Yes

No

Does Membrane

Switch test ok?

Yes

No

Replace Membrane

Switch

Replace Control

Board

12vac from secondary

of transformer?

No

Yes

Replace

Transformer

Check main

wiring harness

41084 102709