FIG. 11 CIRCUIT BREAKER (ULTRA-2)

SERVICE (cont.)

CIRCUIT BREAKER

Location:

The circuit breaker is located inside the dispenser

on the front right frame post on ULTRA-2 models; and

under the Auger Motor cover on ULTRA-1 models.
Test Procedures:

1. Disconnect the dispenser from the power source.

2. Remove the wires from the circuit breaker.

3. Check for continuity between the terminals. Conti-

nuity must be present between the terminals.

If continuity is present as described the circuit breaker

is functioning properly.
If continuity is not present as described, press the reset

button and repeat step #3, if continuity is not present

as described, replace the circuit breaker.
Removal and Replacement:

1. Remove the right side panel on ULTRA-2 models;

or remove the Auger Motor cover on ULTRA-1

models.

2. Remove the wires from the circuit breaker.

3. Compress the clips on the back side of the com-

ponent bracket and gently push the circuit breaker

through the opening in the bracket.

4. Push the new circuit breaker into the opening in

the bracket until the clips snap into position.

5. Reconnect the wires to the circuit breaker.

6. Refer to Fig. 13 when reconnecting the wires.

FIG. 13 CIRCUIT BREAKER TERMINALS

WHI/BLU from Transformer

WHI/YEL to Lamp Relay (ULTRA-2)

RED to Lamp Relay (ULTRA-1)