Bunn -O-MATIC ULTRA-1 User Manual

Page 38

Advertising
background image

38

SERVICE (cont.)

COMPRESSOR (DANFOSS) (ULTRA-1B) (cont.)

GRN

WHI

WHI/ORN to

Overload

Protector

FIG. 30 RELAY TERMINALS

BLK to Compressor

Relay

BLK to Compressor

Relay

FIG. 31 COMPRESSOR CAPACITOR TERMINALS

Removal and Replacement:
Compressor Start Relay: Refer to FIG. 30

1. Remove the terminal cover (4)

2. Disconnect the wires from the compressor start relay.

3. Pull relay (1) off of the compressor pins and discard.

4. Push new relay onto the compressor pins.

5. Refer to Fig. 30 and reconnect the wires.

6. Reinstall terminal cover (4).

Compressor Assy:
NOTE: Before removal of any refrigeration component the

refrigerant in the system must be reclaimed by a licensed

refrigeration repair person.
NOTE: When replacing the compressor it is recommended

that the dryer also be replaced.

1. Disconnect the tubes from the condenser and the ac-

cumulator.

2. Disconnect the compressor wiring harness from the

dispenser main wiring harness.

3. Remove the four .25-20 keps nuts and washers securing

the compressor to the chassis. Set nuts and washers

aside for reassembly.

4. Disconnect and remove the transformer.

5. From the right side of the dispenser lift the compressor

assembly over the four studs in the chassis and remove

compressor.

6. Install new compressor over the four studs in the dis-

penser chassis with the fill valve to the right side of the

dispenser.

7. Secure compressor to the dispenser chassis using four

.25-20 keps nuts and washers.

8. Reconnect tubes from the condenser and the accumula-

tor to the compressor.

9. Reinstall transformer.

10. Evacuate the system.

11. Recharge the 100V system with 6 oz. of Type 404A

refrigerant.

Design Pressures: High 330 - Low 60

NOTE: The charging of the system must be done by a li-

censed refrigeration repair person.
NOTE: Refer to Wiring Diagrams when reconnecting wires

to Compressor, Thermal Overload Protector, Start Relay,

and Run Capacitor.

Compressor Run Capacitor: Refer to FIG. 31

1. Remove terminal cover (4).

2. Disconnect the run capacitor leads.

3. Disconnect the run capacitor from the mounting bracket

located at the front of the dispenser chassis.

4. Remove run capacitor and discard.

5. Snap new run capacitor on the mounting bracket located

at the front of the dispenser chassis.

6. Refer to Fig. 31 and reconnect the wires.

41084 021710