Bunn -O-MATIC ULTRA-1 User Manual

Page 48

Advertising
background image

48

Test Procedures: (Contacts)

1. Disconnect the dispenser from the power source.

2. Disconnect the WHI/VIO and WHI/YEL wires. Con-

nect an ohmmeter across the two coil terminals

where the wires were just removed.

3. Connect the dispenser from the power source..

4. Turn on Power (I/O) Switch. Verify the dispenser

is in the “DAY” mode.

The indication must be:

a) continuity in the “DAY” mode,

b) open in the “NIGHT” mode.

If continuity is present as described, the Relay is op-

erating properly.

If continuity is not present as described, replace the

Relay.

FIG. 52 LAMP RELAY

SERVICE (cont.)

LAMP RELAY

FIG. 51 LAMP RELAY

Location:

The Lamp Relay is located under the upper deck of

the chassis, on the right side.
Test Procedures: (Coil)

1. Disconnect the dispenser from the power source.

2. Connect a voltmeter, across BLU/BLK wire (+) and

the VIO wire (-).

3. Connect the dispenser from the power source.

4. Turn on Power (I/O) Switch. Verify the dispenser

is in the “DAY” mode.

The indication must be:

a) 12 volts dc in the “DAY” mode,

b) 0 volts dc in the “NIGHT” mode.

If voltage is present as described, the Control Board is

operating properly. Replace Relay if it does not energize

when voltage is present.

If voltage is not present as described, refer to the Wiring

Diagrams and check the main wiring harness.

If harness has continuity, replace the Control Board.

ULTRA-2 shown

R

Not Used (N/C)

3 1

4 2

1. (-) 12vdc (VIO) from

Control Board J5-7

2. (+) 12vdc (BLU/BLK) to

Control Board J5-19

3. 12vac (WHI/VIO) to

Lamp Connectors

4. 12vac (WHI/YEL) from

Circuit Breaker

1. (-) 12vdc (VIO) from

Control Board J10-12

2. (+) 12vdc (BLU/BLK) to

Control Board J10-14

3. 12vac (WHI/RED) to

Lamp Connector

4. 12vac (RED) from

Circuit Breaker

ULTRA-2

ULTRA-1

41084 102709

Advertising