Removal and Replacement:

1. Disconnect the lamp cord assembly from the lamp

cord connector assembly in the top of the auger

motor cover.

2. Remove the hopper cover with the lamp cord as-

sembly from the hopper.

3. Remove hopper cover liner from the hopper

cover.

4. Cut off the closed-end splices connecting lamp cord

assembly to the lamp holder/socket assembly.

5. Remove the two lamps.

6. Remove the two #2-56 screws and elastic lock

nuts securing the lamp holder/socket assembly to

the mounting bracket. Remove lamp holder/socket

assembly and discard.

7. Install new lamp holder/socket assembly on mount-

ing bracket using two #2-56 screws and elastic lock

nuts.

8. Reinstall lamps.

9. Strip the wires from the lamp cord assembly ap-

proximately .38”.

10. Using the two wire nuts, supplied, connect the

lamp cord assembly to the new lamp holder/socket

assembly wires.

11. Reinstall the hopper liner to the bottom of the hop-

per cover.

12. Reinstall the hopper cover to the hopper.

13. Plug in the lamp cord assembly to the lamp cord

connector assembly on left top of the auger motor

cover.

14. Refer to Fig. 50 when reconnecting the wires.

FIG. 50 LAMP HOLDER/SOCKET ASSEMBLY

WIRES

P1322

SERVICE (cont.)

LAMP HOLDER/SOCKET ASSEMBLY

FIG. 49 LAMP HOLDER/SOCKET ASSEMBLY

Location:

The lamp holder/socket assemblies are located

inside the hopper covers.
Test Procedures:

1. Disconnect the lamp cord assembly from the lamp

cord connector.

2. Remove the lamps from the lamp holder/socket

assembly.

3. With a voltmeter, check the voltage across the pin

sockets in the plugs in the “DAY” mode. Reconnect

the lamp cord to the lamp cord connector. The

indication must be approximately 12.6 volts dc.

4. Disconnect the lamp cord from the lamp cord con-

nector.

If voltage is present as described, the lamp holder/

socket assembly is operating properly.

If voltage is not present as described, replace the lamp

holder/socket assembly.

5. Check for continuity across the terminals on the

lamps.

If continuity is present as described, the lamps are

operating properly.
If continuity is not present as described, replace the

lamp.