Bunn -O-MATIC ULTRA-1 User Manual

Page 54

Advertising
background image

54

SERVICE (cont.)

TRANSFORMER

FIG. 67 TRANSFORMER TERMINALS

FIG. 65 TRANSFORMER - ULTRA-1

Location:

The transformer is located inside dispenser onthe lower

right side of the chassis.

Test Procedures:

1. Disconnect the dispenser from the power source.

2. Remove right side panel.

3. Connect the dispenser to the power source.

4. Connect a voltmeter from the WHI/BLU wire to the

WHI/BLK wire on the transformer.

The indication must be:

a) Aprox. 12.6 volts ac.

If voltage is present as described, the transformer is

working properly.

If voltage is not present as described, refer to the Wiring

Diagrams and check the main wiring harness.

5. Connect a voltmeter from the WHI wire to the BLK

wire on the transformer.

The indication must be:

a) 120 volts ac for 120 volt models.

b) 230 volts ac for 230 volt models.

If voltage is present as described, replace trans-

former.

If voltage is not present as described, refer to the Wiring

Diagrams and check the main wiring harness.

Removal and Replacement:

1. Disconnect the dispenser from the power source.

2. Remove right side panel.

3. Disconnect the four wires from transformer.

4. Disconnect the wiring harness from the plug on the

transformer.

5. Remove the two #8-32 nuts securing the trans-

former to the chassis base. Remove transformer

and discard.

6. Position new transformer on the chassis base, and

secure with two #8-32 nuts.

7. Refer to Fig. 67 and reconnect the wires.

-LINE-

R

-LINE

-

Ultra-1 WHI/GRY to Main Harness

Ultra-2 WHI/BLK to Main Harness

BLK to Main Harness

WHI to Main Harness

WHI/BLU to

Main Harness

“LOAD”

“LINE”

FIG. 66 TRANSFORMER - ULTRA-2

41084 102709

Advertising