SERVICE (cont.)

FAN - ULTRA-2

FIG. 39 FAN

Location:

The fan is located inside the dispenser chassis just

in front of the condenser.
Test Procedures:

1. Disconnect the dispenser from the power source.

2. Disconnect the gray and white wires from the main

harness to the fan leads.

3. With a voltmeter, check the voltage across the gray

and the white wires. Connect the dispenser to the

power source. In the “ICE” or “CHILL” mode;

The indication must be:

a) 120 volts ac for 120 volt models.

b) 230 volts ac for 230 volt models.

4. Disconnect the dispenser from the power source.

If voltage is present as described, replace the fan.

If voltage is not present as described, refer to Wiring

Diagram and check the dispenser wiring harness.
Removal and Replacement (Refer to Fig. 40)
NOTE: Leave the hopper in place. This keeps it in align-

ment while the condenser shroud is removed.

1. Disconnect the fan leads from the wiring har-

ness.

2. Remove the four #6 crimptite screws securing the

condenser shroud and fan assy (1) to the condenser

and the two #8-32 locking screws securing the

condenser shroud and fan assy (1) to the chassis

base.

3. Remove the condenser shroud and fan assy from

the right side of the dispenser.

4. Remove the three #6 thread cutting screws securing

the fan assy to condenser shroud (7). Set condenser

shroud and screws aside for reassembly.

5. Remove the three #8-32 thread forming screws

securing motor (5) to condenser fan shroud/mount

(6). Set shroud and screws aside for reassembly.

FIG. 40 FAN COMPONENTS

6. Remove speed nut (2) from the motor shaft.

7. Remove fan (3).

8. Remove silencer (4).

1. Condenser Shroud and Fan Assy

2. Speed Nut

3. Fan Blade

4. Silencer

5. Motor

6. Shroud/Mount

7. Condenser Shroud

9. Install silencer (4) on new motor assy.

10. Install fan (3) on new motor assy.

11. Install speed nut (2) on new motor assy.

12. Using three #8-32 thread forming screws secure

new motor assy to shroud/mount (6).

13. Using three #6-32 thread cutting screws secure new

motor and shroud/mount to the condenser shroud

(7).

14. Using two #8-32 locking screws secure condenser

shroud and fan assy (1) to the chassis base.

15. Using four #8-32 crimptite screws secure the con-

denser shroud and fan assy (1) to the condenser.

16. Refer to Fig. 41 and reconnect the leads on the new

motor to the dispenser wiring harness.

17. Use cable ties to secure wires away from fan

blades.

FIG. 41 FAN MOTOR TERMINALS

P1326

BLK to Main Harness WHI

BLK to Main Harness GRY

41084 102709