Bunn -O-MATIC ULTRA-1 User Manual

Page 49

Advertising
background image

49

1

12

1

MEMBRANE
SWITCH

I/O

ULTR

A

GOURMET

IC

E

SHIELD

LEFT

RIGHT

Removal and Replacement:

1. Disconnect the dispenser from the power source.

2. Remove right and left side panels.

3. Remove front panel and disconnect ribbon cable.

4. Peel the old Membrane Swith off the front panel

and discard. Clean any remaining adhesive from

front panel with mineral spirits and then alcohol.

5. Remove protective paper backing from back side

of new Membrane Switch.

6. Guide ribbon cable through narrow slot in panel.

Carefully position new Membrane Switch on panel,

while centering display window to opening.

7. Refer to Fig. 54 and connect the ribbon cable to the

chort harness from the Control Board.

NOTE: The black wire should correspond to the #1

printed on the clear portion of the cable.

FIG. 54 MEMBRANE SWITCH

SERVICE (cont.)

MEMBRANE SWITCH (ULTRA-2)

FIG. 53 MEMBRANE SWITCH

Location:

The membrane switch is located on the front

panel.

Test Procedures:

NOTE: Before continuing, check that the ribbon cable

is properly connected to the control board and not a

pin off in either direction.

1. Disconnect the dispenser from the power source.

2. Remove the right and left side panels.

3. Remove the front panel and disconnect ribbon

cable.

4. Check for continuity of the switches using pin #7

as common.

#7 - #1 (shield) no continuity

#7 - #2 (Left Auger)

#7 - #3 (I/O)

#7 - #4 (not used)

#7 - #5 (Left ICE/CHILL/OFF)

#7 - #6 (ULTRA)

#7 - #8 (GOURMET)

#7 - #9 (not used)

#7 - #10 (ICE)

#7 - #11 (Right Auger)

#7 - #12 (Right ICE/CHILL/OFF)

If continuity is not present when the appropriate switch

is pressed, the Membrane Switch must be replaced.

If continuity is present, chech the short harness going

to J2 on the Control Board.

FIG. 55 MEMBRANE SWITCH

and RIBBON CABLE

41084 102709

Advertising