Bunn -O-MATIC ULTRA-1 User Manual

Page 24

Advertising
background image

24

FIG. 4 AUGER MOTOR CAPACITOR TERMINALS

SERVICE (CONT.)

AUGER MOTOR CAPACITOR

FIG. 3 AUGER MOTOR CAPACITORS

P1341

Location:

The auger motor capacitor(s) are located on the lower

right side of the auger motor mounting bracket inside the

auger motor cover(s).

Test Procedures

1. Remove the hopper from the same side as the motor

to be tested.

2. Turn “ON” the appropriate auger switch.

3. Nudge the auger to start it turning.

If the auger doesn’t turn, replace the motor.

If auger starts to turn, replace the start capacitor.

WARNING: The compressor start capacitor must be properly

discharged before removing. This is most commonly done

on low voltage capacitors by shorting across the terminals

with a screwdriver.

ULTRA-2 shown

Removal and Replacement

1. Remove the two #8 locking screws securing the auger

motor cover to the cooling drum mount assy.

2. Remove the cover and set aside for reassembly.

3. Disconnect the wires from the auger motor capacitor

terminals.

4. Remove the #8 locking screw on the lower right side of

the auger motor mounting bracket securing the auger

motor capacitor.

5. Install a new capacitor on the lower right side of the

auger mounting bracket and secure with a #8 locking

screw.

6. Reconnect the wires to the capacitor terminals.

7. Refer to Fig. 4 when reconnecting the wires.

ULTRA-2 LEFT MOTOR CAPACITOR

BRN/WHI to Left Auger Motor J13-2

BRN/BLK to Control Board J13-3

ULTRA-2 RIGHT MOTOR CAPACITOR

WHI/RED to Right Auger Motor J13-13

RED/BLK to Control Board J13-1

ULTRA-1 AUGER MOTOR CAPACITOR

BRN/WHI to Auger Motor J10-8

BRN/BLK to Control Board J10-9

41084 102709

Advertising