FIG. 62 TEMPERATURE SENSOR

SERVICE (cont.)

TEMPERATURE SENSOR

FIG. 61 TEMPERATURE SENSOR

P1341

Location:

The Temperature Sensor(s) are located inside the

top rear of the cooling drum under the Auger Motor

covers.
Test Procedures:

1. Remove the left side housing panel.

2. Connect a voltmeter, across the two leads of the

temperature sensor (leave plug connected);

The indication must be:

a) Approx. 1.4 vdc @ 71° F

b) Approx. 2.6 vdc @ 32° F

If voltage reading is 0v, the Control Board is not sup-

plying the necessary 5v and should be replaced. If the

reading stays at 5vdc, replace thermistor.

Alternate Test:

2. Disconnect the plug on thermistor leads and check

resistance as indicated below.

The indication must be:

a) 5650 ohms @ 32° F ± 10%

b) 2000 ohms @ 77° F ± 10%

If resistance reading is not within the range listed above,

replace thermistor.

Removal and Replacement:

1. Remove the two #8-32 screws securing the auger

motor cover to cooling drum mount and remove

cover. Set aside for reassembly.

2. Disconnect the plug on the temperature sensor

leads from the connector on the dispenser main

harness.

3. Pull the temperature sensor from the tube at the

top rear of the cooling drum and discard.

4. Push new temperature sensor into tube at the top

rear of the cooling drum as far as it will go.

5. Refer to Fig. 62 and reconnect the wires.

6. Position auger motor cover on cooling drum mount

and secure with two #8-32 locking screws.

ULTRA-2 shown

1. Ultra-2 Left Temperature Sensor

WHI to TAN J13-21

(Control Board) Positive

1. Ultra-2 Right Temperature Sensor

WHI to PNK J13-22

(Control Board) Positive

1. Ultra-1 Temperature Sensor

WHI to TAN J10-3

(Control Board) Positive

2. WHI to WHI/BLK Main Harness

(Control Board) Negative

2 1