Data Specifications

When communicating via the serial data port (RS-232), the baud
rate, number of data bits, and the parity are user-selectable (see
Section 4 for acceptable setting combinations). Parity only
applies to data transmitted by the printer, since it ignores the parity
of received data. The M-Series Printer is fixed at 1 stop bit, so
make sure that your host is also set at 1 stop bit.

When communicating via the parallel port, the previously
mentioned parameters are not considered.

RS-232 Serial Data Port

The connections for the standard interface are made through the
DB25S connector on the rear panel. For all RS-232 input and output
signals, the M-Series Printer follows both the Electronics Industries
Association’s (EIA) RS-232 and the Consultative Committee for
International Telegraph and Telephone (CCITT) V.24 standard
signal level specifications.

Pin No.

Description

1

Frame Ground for Cable Shield

2

TXD (Transmit Data) output from the printer

3

RXD (Receive Data) input to the printer

4

RTS (Request To Send) output from the printer

6

DSR (Data Set Ready) input to the printer

7

Signal Ground

20

DTR (Data Terminal Ready) output from the printer

Note: Pins 5, 8, 10-19, and 21-25 are not used and are unterminated.

Table 5.1 RS-232C Pinouts