Brady 200M User Manual

Page 65

Advertising
background image

Refer to Figures 7.3 and 7.4 while performing this procedure.

1. Position the upper media sensor (approximately 1 inch from

the sensor guide plate edge) such that as the locator is
dropped in place, the sensor (Phillips head screw) will pro-
trude through the locator slot.

2. Place the locator on the sensor guide plate so that the three lo-

cator pins (see Figure 7.4) fit securely in the sensor guide
plate slot. Make sure the locator slot is positioned to the in-
side of the printer near the printer fire wall.

Note: The magnetic surface of the locator will eliminate the

chance of it becoming accidentally dislodged.

3. The sensor can now be easily repositioned to meet the media

requirements:

Position A is for all Brady THT products except Per-
mashield and Permasleeve.

Position B is for Brady Permashield and Brady Per-
masleeve.

Figure 7.3 Sensor Guide Plate

Figure 7.4 Locator

Adjustments

M-Series User ’s Guide

7-4

Advertising
This manual is related to the following products: