Brady 200M User Manual

Page 67

Advertising
background image

Lower Transmissive Media Sensor Position Adjustment

To adjust the lower media sensor, follow these steps.

1. Locate the lower media sensor assembly (a spring clip holding

a small printed-circuit board) under the rear idler roller.

2. Position the sensor so that the two brass-colored infrared emit-

ters are under the upper sensor by sliding it in its slot.

3. Gently pull wires out of the printer frame as required. (Wires

should have a little slack.)

Note: If the sensor is being moved inward and a large loop of

wire develops, remove the cover from the electronics side
of the printer and gently pull the wires through. It is
important that the wires be properly clamped so that they
are not rubbed by any belts.

Figure 7.5 Lower Transmissive Media Sensor Locations

Adjustments

M-Series User ’s Guide

7-6