General Maintenance

To change elements:

1. Pull the air cleaner cover lock (Figure 63, 1) OUT, turn the air

cleaner cover (2) counter-clockwise and remove cover from air
cleaner canister (3).

Figure 63

2. Remove the primary element (Figure 64, 1). Inspect element for

damage. Damaged elements should not be reused.

3. Thoroughly clean the interior of the air filter canister (Figure 64, 2)

and vacuator valve (3).

4. If replacing the inner safety element (Figure 64, 4) at this time,

carefully slide the inner safety element out. Always discard this ele-
ment and replace with a new element.

5. Slide the new primary element over the inner safety element mak-

ing sure the sealing edge is flush with the base of the air cleaner.

IMPORTANT! DO NOT apply any type of petroleum product to the sealing
surface of the filter in an attempt to get a more positive seal. This will cause
sealing surface damage and allow dirt to by-pass the filter. Use liquid
dishwashing soap (Ivory, Dawn, etc.) on the seal of the filter only.

6. Position canister cover (Figure 64, 5) in place, turn clockwise to

lock into position and secure in place by pushing the air cleaner
cover lock (6) all the way in.