General Maintenance

119

Model 6036

C. Replace In-line Fuel Strainer

(250 Hour Intervals)

1. Unlock and open the right rear engine access door.

2. The in-line fuel strainer (Figure 74, 1) is located down line from the

engines lift pump (2). Loosen the two hose clamps (3) that secure
the strainer in place.

3. Remove the old in-line fuel strainer and dispose of properly.

4. Install the new in-line fuel strainer (Figure 74, 1) with arrow pointing

toward the lift pump (2).

5. Assemble the hoses to the in-line fuel strainer and tighten the hose

clamps.

6. Remove air from the fuel system (see “Bleeding Fuel System” on

page 120).

7. Close and lock the right rear engine access door.

Figure 74

500

OT1150

OH2200

1

2

3